Vue de la page 11
821667: VAMP2 Series User Guide
© 2012 Wohler Technologies, Inc. All rights reserved.
10
VAMP2 Series User Guide
Specifications
Table 1–6 Level Meter Specifications
Specification Values
Level Meter Type Bar Graph
Segment Quantity 53
Level Meter Scale 0 to -66 dB
Dynamic Range 66 dB
Mid-scale Resolution 1 dB
Bar Graph Length 2.22” (56.4 mm)
Indication Accuracy
+10 to -30 dB
-31 to -44 dB
-45 to -55 dB
± 0.2 dB
± 0.3 dB
± 0.5 dB
Segment Display Colors red, amber, green
Peak Emission Wave
Length
Green=570 nm; Red=630nm
Segment Brightness
(20 mA)
3.5 mcd
Segment Brightness
Uniformity
<10% difference between segments
Adjacent Segment “Off”
Brightness
<1% of brightness of active segment
Segment Size 0.158” x 0.04” (4 mm x 1 mm)
Segment Pitch 0.039” (.99 mm)